Patch Panel Layout Programs
Enterprise Networking Routers, Switches, Firewalls and other Data Networking infrastructure discussions welcomed. New Visitors are encouraged to read our. This subreddit allows:. Enterprise & Business Networking topics such as:.
Design. Troubleshooting. Best Practices. Educational Topics & Questions are allowed with following guidelines:. Enterprise /Data Center /SP /Business networking related. No Homework Topics without detailed, and specific questions.
This is specifically related to the patch panel and switch layout. Do you prefer all patch panels together and then all switches together [as seen. DESIGN: Software tools aid the cabling professional. Staff will determine how quickly they learn to use software programs. A patch panel into a relay.
Networking Career Topics are allowed with following guidelines:. Topics asking for information about getting into the networking field will be removed. This topic has been discussed at length, please use the search feature.
Topics regarding senior-level networking career progression are permitted. This subreddit does NOT allow:. Home Networking Topics. We aren't here to troubleshoot your 'advanced' video game latency issues. Home Networks, even complex ones are best discussed elsewhere like. HomeLab discussions, as a tool for learning & certifications are welcomed.
Braindump / Certification Cheating. These topics pollute our industry and devalue the hard work of others.
These posts will be deleted without mercy. Blogspam / Traffic Redirection.
This sub prefers to share knowledge within the sub community. Directing our members to resources elsewhere is closely monitored.
You may announce the existence of your blog/YouTube Channel. You may share a URL to a blog that answers questions already in discussion. But harassing members to check out your content will not be tolerated. Low-quality posts. Any post that fails to display a minimal level of effort prior to asking for help is at risk of being Locked or Deleted. We expect our members to treat each other as fellow professionals. Professionals research & troubleshoot before they ask others for help.
Please review to avoid this issue. Early-Career Advice. This sub-reddit is dedicated to higher-level, more senior networking topics. and are all available for early-career discussions. We don't do your homework for you.
Don't ask us what we would buy for a given project. Don't ask us how to subnet.
Show us how you think you should solve those issues, and we will validate or offer enhancement to your initial attempt. Recommended & Related Sub-Reddits: Related IRC Channels. Rule #1: No Home Networking. Rule #2: No Certification Brain Dumps / Cheating. Rule #3: No BlogSpam / Traffic re-direction. Rule #4: No Low Quality Posts.
Rule #5: No Early Career Advice. Rule #6: Homework / Educational Questions must display effort.
We just built an IDF in a new building on our campus, and it came out really nice. Three 2-post racks, with 12' Vertical cable management. The leftmost rack is for A/V and MAN connections, the middle rack is for access-layer growth (currently unused), and the rightmost rack houses our 4510 and five 48-port angled patch panels. Patch panels are all together, with the 4510 at the bottom of the rack. Once we have everything dressed in and connected, I'll snap a couple pictures for you guys. This is going to be our new standard for 2-post IDF construction. It's really nice.
Angled patch panels in the top of the rack with switches in the lower half. Vertical finger wire managers down the sides of the racks, 8' wide on the ends and 12' between racks if we have the room. This isn't one of my closets but this is what our setup looks like.
We don't put in that big panduit pass through horizontal manager, we put in a smaller 2u one in the middle of the rack and one at the top of the rack. This setup handles density well, we can run 10 patch panels and 8 switches in the 1 rack.
I think it really depends on the switches jobs. External DMZ/HSRP/VRRP switches which only have a couple ethernets in them, maybe don't require an entire 1u or 2u patch or cable management above and below them. However, when you're talking about access switches, stacks of 5x48 ports, then fuck, you could go half one way, half the other way, no matter what in 5 years the shit is going to look like spaghetti. Unless you're the only network engineer, and you did the whole design/move/whatever, it'll look completely different in a few years. This is mainly access switches, core switches typically stay the same unless you get some idiot who cant figure shit out and you'll have a long ass blue cable hanging from the front of something.
At that point your port channels won't work and STP has been disabled.
Patch Panel Cable Management Software Data center teams often find themselves tracing cables within their data center due to outdated, inaccurate patch panel records (usually Excel or Visio files). Worse yet, some data centers lack any tools for managing the ever expanding, ever changing sea of patch panel connections. Fortunately, data center cable management doesn’t have to be daunting, time consuming, and error prone. With Device42 software, keeping track of your patch panel cable connections is fast, easy, and accurate. Device42 removes cable management complexity and increases the visibility, control, and efficiency of data center cable management.
Template Based Patch Panels Device42’s template-based, data center patch panel diagrams allow IT staff to quickly create custom patch panel diagrams that provide instant clarity to cable connections. When creating new patch panel records, IT staff can chose an existing patch panel template or create an entirely new patch panel model “on the fly”.
Patch panel templates make building patch panel documentation easy, and fast:. Flexible port types - singular (all ports the same), or modular (mixed port types). User-defined port types provide complete flexibility. User-defined port types allow you to create the port type to suit your needs. Track individual fiber strands with paired ports.
Powerful Patch Panel Visualization Device42’s template-based data center patch panel diagrams make patch panel record keeping easy and fast. Patch panel diagrams clearly display connections and instantly convey connection details needed for effective patch panel management.
Visual patch panel layouts are easy to use. Users can quickly access detailed port information. Color coded icons clearly show connection status. Mouse-over cables to view local or remote – ports and devices.
View physical connections to local devices. Use iOS and Android Devices for Patch Panel Management While Device42 provides centralized visibility and control of data center infrastructure, it also provides mobile workers with access to the data center information they need while away from their desk – making patch panel adds, changes, and audit work both faster and easier.+. Use iOS or Android devices to access data while inside the data center. Web-based UI works with all the popular browsers and is great on tablets. Provide data center with the information they need in real-time. Complete Patch Panel Cable Management Device42 enables proactive patch panel management.
Leviton 48 Port Patch Panel Layout Excel
Clear visualizations and linked detailed information allow data center managers to take control of complex patch panel wiring and avoid the likely problems and costs associated with poor patch panel management. Manage your patch panels efficiently and effectively. Load cabling data quickly using spreadsheet imports. Manage cabling data using easy-to-use web-based GUI. Visualize end-to-end connectivity using patch panel layouts. Quickly determine port availability and port status Device42 is trusted by the brands that you trust.